TPS-Low

TPS-ULP – pressure sensor

The digital ultra-low-pressure sensors of the TPS-ULP series combine modern MEMS pressure sensing elements with CMOS mixed-signal processing in a compact SOIC-16 package. The result is a fully calibrated and temperature-compensated digital low-pressure sensor that, depending on the version, features vertical or horizontal dual-port pressure connections. The series includes uni- and bidirectional gauge and differential pressure models.

The total error band after PCB mounting and system-level autozero is below 1 %FS across the entire compensated temperature range from −20 to 85 °C. The stable warm-up behavior and excellent long-term stability underline the sensor’s reliability over its full lifetime.

The newly developed, integrated signal-conditioning ASIC allows the configuration of internal filters as well as checksums to ensure data integrity of this modern micromechanical silicon pressure sensor. The TPS-ULP can be soldered directly onto the PCB in standard SMT processes as an SOIC-16 device. Via the 24-bit I²C interface, both a calibrated pressure signal and a temperature signal are available. External compensation networks or additional customer-specific correction circuits are not required.

The TPS-ULP series is currently available for pressure ranges of ±150 Pa, ±250 Pa and 0 … 500 Pa. Higher pressure ranges from 5 mbar up to  2 bar are available as TPS-LP and TPS-MP differential and gauge pressure sensors.

TPS products are supplied in Tape & Reel packaging.

Further information on the general structure of this sensor technology can be found in our whitepapers on functionality and package types: Whitepaper AMSYS

Features

  • Pressure ranges: ±150 Pa, ±250 Pa, 0 … 500 Pa
  • Pressure type: Gauge / unidirectional differential (0 … Pmax), Bidirectional differential (±Pmax)
  • 24-bit ADC
  • 24-bit I²C output
  • Total Error Band (TEB): ±1 %FS
  • Pressure-calibrated and temperature-compensated output
  • Compensated temperature range: −20 to 85 °C
  • Operating temperature range: −40 to 105 °C
  • Extended diagnostics incl. communication and memory check
  • Supply voltage range: 3.0 … 5.5 V
  • Sleep-mode current consumption: <1.8 µA

Applications

  • CPAP / Sleep apnea
  • Ventilators / Respiratory devices
  • Gas flow instrumentation
  • Airflow measurement
  • HVAC / VAV
  • Leakage monitoring
  • Filter monitoring

Article & Ordering Information

Part Number Designation Pressure Range Ports
20032216-00 TPS-250PG-BA1N-00-T 0 – 250 Pa horizontal
20032074-00 TPS-250PG-CA1N-00-T 0 – 250 Pa vertical
20032217-00 TPS-300PG-BA1N-00-T 0 – 300 Pa horizontal
20032075-00 TPS-300PG-CA1N-00-T 0 – 300 Pa vertical
20032218-00 TPS-500PG-BA1N-00-T 0 – 500 Pa horizontal
20032002-00 TPS-500PG-CA1N-00-T 0 – 500 Pa vertical
20032022-00 TPS-500PG-CA2N-00-T 0 – 500 Pa vertical
20032219-00 TPS-600PG-BA1N-00-T 0 – 600 Pa horizontal
20032215-00 TPS-125PD-BA1N-00-T -125 – 125 Pa horizontal
20032072-00 TPS-125PD-CA1N-00-T -125 – 125 Pa vertical
20032214-00 TPS-150PD-BA1N-00-T -150 – 150 Pa horizontal
20032001-00 TPS-150PD-CA1N-00-T -150 – 150 Pa vertical
20032213-00 TPS-250PD-BA1N-00-T -250 – 250 Pa horizontal
20032073-00 TPS-250PD-CA1N-00-T -250 – 250 Pa vertical
20032076-00 TPS-600PD-CA1N-00-T -600 – 600 Pa vertical

For information on prices and delivery times or if you have any technical questions, please contact info@amsys-sensor.com.