With a footprint of only 7.6 x 7.2 mm², the AMS 6836 sensors housed in a DIL-6 package are among the smallest differential pressure sensors on a robust ceramic substrate. The tiny pressure sensors are designed for precision pressure measurements in the low and very low pressure range and are available for pressure ranges from 125 Pa to 2000 mbar. AMSYS thus offers a pressure sensor with a precise ratiometric analog output in an extremely small package.
The pressure sensors are extensively calibrated and compensated, featuring extremely small measurement errors at room temperature as well as a very low total error in the compensated temperature range of -25 to 85 °C of only 0.5 to 2 %FS (depending on the pressure range).
Pressure variants and ranges of the AMS 6836
Ultra low pressure differential / relative: 0 .. 250; 0 .. 500, 0 .. 1,000, and 0 .. 1,250 Pa
Ultra low pressure bidirectional differential: ±125; ±250; ±500, ±1,000, and ±1,250 Pa
Low pressure differential / relative: 0 .. 20, 0 .. 35, 0 .. 50, and 0 .. 100 mbar
Low pressure bidirectional differential: ±20, ±35, ±50, and ±100 mbar
Medium pressure differential / relative: 0 .. 200, 0 .. 350, 0 .. 500, 0 .. 1,000, and 0 .. 2,000 mbar
Medium pressure bidirectional differential: ±200, ±350, ±500, and ±1,000 mbar
Absolute pressure: 0 .. 500, 0 .. 1,000, 0 .. 1,500, 0 .. 2,000 mbar
Barometric: 700 .. 1,200 mbar
Compared with the analog/digital AMS 5812—which is ideally suited for medical applications featuring a ceramic cap and stainless-steel pressure ports—the AMS 6836 offers a space-saving alternative with a modern ASIC in a plastic housing.
Note: The AMS 6836 can be custom calibrated regarding the pressure range as well as for lower supply voltages. Special designs, such as different pressure connections, are also available upon request.
You will find more detailed explanations regarding the general design and functional principle of these pressure sensors in our whitepapers section here: AMSYS Whitepaper
Features
- Pressure ranges: 0 to 250 Pa to 0 to 2,000 mbar differential/relative
±125 Pa to ±1,000 mbar bidirectional differential
0 .. 500 mbar to 0 .. 2 bar absolute - Output signal pressure: analog voltage 0.5 .. 4.5 V
- Pressure connection: horizontal tube connection
- Housing/size: DIL-6, 7.6 x 7.2 mm²
- Operating temperature: -25 to 85 °C
- Power supply: 4.5 to 5.5 V
- RoHS and REACH compliant
- Product made in Germany
Applications
Medical technology
- Ventilators
- Sleep apnea therapy devices (CPAP)
- Spirometers
- Anesthesia devices
- Dialysis machines
- Infusion pumps
- Oxygen concentrators
- Vacuum suction pumps
- Insufflators
- Blood glucose meters
- Pulse oximeters
- Computed tomography (CT)
HVAC and measurement technology
- Volumetric flow measurement
- Duct pressure monitoring
- Room pressure monitoring
- Filter monitoring
Downloads
- AMS 6836 pressure sensor datasheet
- Media compatibility of silicon pressure sensors: Media compatibility PDF
- Ratiometry in pressure sensing: Ratiometry PDF
For information on prices and delivery times or if you have any technical questions, please contact info@amsys-sensor.com.